Process Control Home
 
Alpha Controls
 

Medical Air Dew Point Monitor from EdgeTech

Why do I need the new DPM-99 Medical Air Dew Point Monitor?

Performance that exceeds the latest requirements of NFPA99 for Med Gas Dew Point Monitoring
NIST traceable Dew Point
Continuous Dew Point Monitoring
Easy to install, virtually maintenance free

Patient Safety

The NFPA99 has mandated that for Med Gas systems the "dew point for locally compressed air shall be monitored and alarmed per 4-3.1.9.8 and 4-3.1.1.2(f) to protect from a line pressure dew point rise to 39°F (3.9°C) from a nominal design of 35°F(1.7°C)." This safeguard was the foundation for the new EdgeTech and
AIRVAC Technical Services DPM-99 Med Gas Dew Point Monitor. This specifically designed monitor exceeds the requirements set-forth by the NFPA and was a collaboration with AIRVAC Technical Services who are certified by P.IP.E as medical gas inspectors in all 50 US states.

Reliable
The DPM-99 Medical Air Dew Point Monitor utilizes a chilled mirror sensor, the most accurate reliable dew point sensing scheme. This primary measurement is directly traceable to N.I.S.T.. The DPM-99 also uses a modified Automatic Balance Cycle (ABC) that allows for continuous monitoring of dew point with virtually maintenance-free operation. Dew point is monitored continuously for safety in the DPM-99 Medical Air Dew Point Monitor in comparison to only 5% of the time as touted by other manufacturers.

Easy to Install
The DPM-99 is a complete Dew Point Monitoring system. It consists of the sensor, Audible & Visual Alarms, and flow controller contained within an easily mountable ruggedized aluminum NEMA-12 enclosure. Only 1 sample line and power connections need to be made to become immediately compliant.

Why do I need this Dew Point Monitor?
Because the NFPA99, section 4-5.1.5 requires dew point levels be monitored and maintained below 39°F(3.9°C). This is not only to protect expensive equipment such as ventilators and respirators but most importantly the end-user: THE PATIENT. The EdgeTech DPM-99 Medical Air Dew Point Monitor surpasses the requirements set-forth by the NFPA.

Should I upgrade?
Older systems that are "grandfathered" should be upgraded for peace of mind that your Med Gas system is not endangering patients with dew points that are higher than the 39°F (3.9°C) mandated by the NFPA.



Powerful Solutions for Instrumentation & Control Problems!

Medical Air Dew Point Monitor from EdgeTech

Site Designed By Panther Marketing